60" x 60" Smoke Vent for Cold Storage Facilities

BA-ASV-CS-60-60
60" x 60"

video icon

60" x 60" BA-ASV-CS Smoke Vent for Cold Storage Facilities

The 60" x 60" BA-ASV-CS Smoke Vent for Cold Storage Facilities is engineered for the extreme temperature demands of refrigerated warehouses and freezer environments. Its insulated curb and lid reduce heat transfer through the roof opening while providing dependable smoke release for freezer and cold-storage facilities.

Its customizable base flanges fit insulated metal panel roofs or conventional built-up systems, making it a purpose-built venting solution for cold storage roofs.

Why Choose 60" x 60" BA-ASV-CS Smoke Vent for Cold Storage Facilities?

  • Cold-Storage Thermal Design: A fully thermally broken curb and lid with 6" polyiso insulation minimizes thermal loss in freezers and refrigerated warehouses.
  • Automatic Smoke Release: A heat-activated UL-listed fusible link releases the vent automatically when temperatures rise, available in multiple temperature ratings from 165 degrees F to 520 degrees F.
  • Built for Demanding Roof Conditions: Available in aluminum or galvanized steel construction, the BA-ASV-CS withstands harsh rooftop environments while helping reduce long-term maintenance requirements.
  • Engineered for Load: The lid is designed for 40 PSF live loads and 30 PSF uplift, helping the vent perform reliably in facilities where roofs experience maintenance traffic and environmental loads.
  • Complete Perimeter Seal: An extruded EPDM bulb gasket in two rows seals the entire curb opening to help maintain the cold environment.
  • Controlled Operation: Low spring-rate nitrogen gas springs provide smooth, controlled lid operation, with interior and exterior manual releases.

Not sure if the BA-ASV-CS is the right fit for your cold storage roof application? Browse our full range of roof access solutions and compare your options.

• Key Product Specifications

  • Nominal Size: 60" x 60"
  • Thermal Rating: R-39 thermally broken system with 6" polyiso insulation
  • Lid:080" reinforced aluminum with 6" polyiso insulation and liner
  • Curb: 12" high thermally broken curb with 6" polyiso insulation
  • Curb Construction:125" aluminum or 14-gauge galvanized steel
  • Lid Load Rating: 40 PSF live load
  • Uplift Rating: 30 PSF
  • Opening Load: Designed to open against a 10 PSF snow load
  • Fusible Link: Heat-activated, UL-listed; available in 165°F, 212°F, 286°F, 370°F, or 520°F ratings
  • Manual Release: Interior and exterior manual releases
  • Gaskets: Full perimeter extruded EPDM bulb gasket
  • Springs: Nitrogen gas springs
  • Hold-Open Mechanism: Automatic aluminum or steel hold-open channel
  • Latches: 12-gauge mechanical latches rated for 90 PSF uplift,
  • Optional latches: Zinc-plated or stainless steel
  • Base Flange: Customizable for insulated metal panel roofs or conventional built-up roof systems

What Comes Standard and What Can Be Configured?

Every BA-ASV-CS is engineered with the following as standard:

  • 080" aluminum reinforced lid with 6" polyiso insulation
  • 12" high thermally broken curb with 6" polyiso insulation
  • Heat-activated UL-listed fusible link
  • Two-row extruded EPDM bulb perimeter gasket
  • Low spring-rate nitrogen gas springs
  • Interior and exterior manual releases

The following should be specified at the time of order:

  • Construction material (0.125" aluminum or 14-gauge galvanized steel)
  • Powder coat finish or kynar finish
  • Fall protection screen or security bars
  • Heat trace at curb opening
  • zinc plated or stainless-steel latches
  • McCabe resettable electronic release link
  • Fusible-link temperature rating (165 to 520 degrees F)
  • Base flange configuration for your roof system

What to Know About Rough Opening and Installation Requirements?

Required Roof Opening

The BA-ASV-CS is set into a roof curb opening sized per the submittal drawing for your specified dimensions, with the base flange configured to your roof system. Confirm the opening, roof buildup, and flashing details with your design team before installation.

Compatible Applications

This vent is designed for cold storage and freezer roof systems. Typical uses include:

  • Refrigerated warehouses
  • Freezer facilities
  • Food processing plants
  • Cold storage distribution centers

Installation Notes

  • Select the correct base flange configuration for insulated metal panel (IMP) or conventional roof systems before fabrication.
  • Flash the curb to the roof system per the project's roofing details.
  • The fusible link enables automatic release; interior and exterior manual releases are also provided.
  • Lids open against a 10 PSF snow load.
  • Confirm the fusible-link temperature rating matches the facility's smoke vent design requirements.

Looking for more general smoke vent installation and safety guidance? Explore our installation resources packed with practical insights for getting the job done right.

Who Specifies BA-ASV-CS and Where Is It Used?

The BA-ASV-CS is typically specified by architects, mechanical and fire-protection engineers, roofing contractors, and facility managers responsible for smoke ventilation in refrigerated buildings.

Common applications include:

  • Refrigerated warehouses - roof smoke ventilation
  • Freezer facilities - thermally efficient smoke vents
  • Food processing plants - rated roof venting
  • Cold storage distribution hubs - large-facility smoke release
  • Pharmaceutical cold storage - controlled-environment venting

Do you order access solutions often or in bulk? Pro Club gives contractors access to exclusive pricing, priority support, extended return periods, and member-only resources designed to simplify product selection and repeat purchasing. See if you qualify.

Frequently Asked Questions About Cold Storage Smoke Vents

1. What makes this smoke vent suited to cold storage?

Unlike standard smoke vents, the BA-ASV-CS combines a fully thermally broken curb and lid with 6" polyiso insulation to help reduce thermal bridging and preserve freezer efficiency while still providing automatic smoke ventilation.

2. How does the vent open in a fire?

A heat-activated UL-listed fusible link releases the lid automatically when temperatures rise. It is available in ratings from 165 to 520 degrees F, and interior and exterior manual releases are also provided.

3. What construction materials are available?

You can choose 0.125" aluminum or 14-gauge galvanized steel, with a 0.080" aluminum reinforced lid, depending on the application.

4. Will the vent fit my roof system?

The base flanges are customizable to fit insulated metal panel (IMP) roofs or conventional built-up systems. Specify your roof type at the time of order.

5. What loads is the vent designed for?

The lid is engineered to withstand a 40 PSF live load and 30 PSF uplift for demanding roof conditions.

Get Cold-Storage Smoke Venting for Your Facility

Struggling to meet smoke-ventilation requirements without compromising your facility’s thermal performance? The 60" x 60" BA-ASV-CS Smoke Vent for Cold Storage Facilities may be the product you’re looking for.

Contact us or call +1-888-327-5471 to confirm the right size, material, fusible-link rating, and base configuration for your cold-storage roof or request a quote.

Product Downloads

BA-ASV-CS-60-60

Have a Product Question?

Ask a question about this: BA-ASV-CS-60-60

  • Request Product Information

Real Reviews From Real Customers

Real Reviews From Real Customers