Description
22" x 30" BA-PFI Fire-Rated Insulated Access Door with Exposed Flange
The BA-PFI 22" × 30" Fire Rated Insulated Access Door with Exposed Flange provides code-compliant access to concealed building systems installed within fire-rated wall and ceiling assemblies.
Constructed with a 20-gauge galvanneal steel door, a 16-gauge cold rolled steel frame, and 2-inch mineral wool insulation, it is designed for projects that require dependable access while preserving the fire-resistance performance of the surrounding assembly. Its exposed flange simplifies installation across drywall, masonry, and other approved substrates while maintaining a clean finished appearance.
Why Choose BA-PFI 22" × 30" Fire Rated Insulated Access Door with Exposed Flange?
- Meets Fire-Rated Wall and Ceiling Requirements: The BA-PFI 22" × 30" is tested for use in qualifying fire-rated wall and ceiling assemblies. It achieves up to a 3-hour fire rating in vertical wall assemblies and up to a 3-hour rating in non-combustible ceilings. It has a 1-hour rating in combustible ceilings when installed in accordance with the manufacturer's instructions and applicable code requirements.
- Combines Durable Steel and Mineral Wool Construction: This model features a 20-gauge galvanneal steel door and standard 2-inch mineral wool insulation. These components work together to form the door's tested fire-rated construction while providing a durable access solution for commercial and institutional applications.
- Includes Complete Standard Operating Hardware: Every BA-PFI comes equipped with a continuous piano hinge, an automatic panel closer, a self-latching tool-key operated slam latch, and a ring-operated slam latch. This means the panel can be opened from within the access area.
- Supports Multiple Fire-Rated Installation Types: The BA-PFI can be installed in gypsum walls, gypsum ceilings, and masonry walls when the appropriate installation procedures are followed. Separate installation methods accommodate each assembly type, providing flexibility across a variety of commercial building projects.
- Offers Flexible Specification Options: Beyond its standard configuration, the BA-PFI can be specified with optional features such as a mortise deadbolt lock, handle-operated slam latch, hex head slam latch, mortise preparation for a cylinder lock, stainless steel construction, and masonry anchors to suit specific project requirements.
Explore our fire-rated access doors category to discover a complete range of sizes, materials, fire ratings, and hardware options designed to meet the requirements of commercial, institutional, and residential projects.
What Comes Standard and What Can Be Configured?
The BA-PFI 22" × 30" includes a range of standard components for fire-rated wall and ceiling applications, along with optional hardware and material configurations that can be specified during ordering. Reviewing these options before placing an order helps ensure the access door is configured for the intended application.
Standard Features
Every BA-PFI 22" × 30" includes:
- 16-gauge cold rolled steel frame
- 20-gauge galvanneal steel door
- 2-inch mineral wool insulation
- Continuous piano hinge
- Automatic panel closer
- Self-latching tool-key operated slam latch
- Ring-operated slam latch
- Inside panel release (standard on doors larger than 12" × 12")
- High-quality white powder coat primer finish
- Individually wrapped packaging, one per box
Optional Configurations
The BA-PFI can also be specified with the following options:
- Mortise deadbolt lock
- Hex head slam latch
- Handle-operated slam latch
- Mortise preparation for a cylinder lock
- Type 304 stainless steel with No. 4 brushed finish
- Masonry anchors (available on all sizes)
Need help selecting the right hardware or material option? Contact our team to compare available configurations, discuss your project requirements, and identify the BA-PFI that best fits your application. Our specialists can help you evaluate material choices, hardware options, and sizing requirements to streamline specifications.
What Are the Key Specifications of BA-PFI 22" × 30"?
The BA-PFI 22" × 30" combines fire-rated construction, insulated steel components, and standard operating hardware in a configuration designed for qualifying wall and ceiling assemblies. Below are the primary specifications for this model.
- Door size: 22" × 30" (558 × 762 mm)
- Rough wall opening: Door size + ¼" (6 mm)
- Weight: 30 lbs (13.6 kg)
- Door material: 20-gauge galvanneal steel
- Frame material: 16-gauge cold rolled steel
- Frame depth: 2½"
- Insulation: 2-inch mineral wool
- Hinge: Continuous piano hinge
- Automatic panel closer: Standard
- Standard latches: Self-latching tool-key operated slam latch and ring-operated slam latch
- Inside panel release: Standard on all doors larger than 12" × 12"
- Finish: High-quality white powder coat primer
- Vertical wall fire rating: Up to 3 hours (neutral/negative pressure)
- Horizontal ceiling fire rating: Up to 3 hours in non-combustible construction and up to 1 hour in combustible construction
- Packaging: Individually wrapped, one per box
- Custom sizes: Available
LEED Compatibility
The BA-PFI is identified as LEED Ready. Consult the project documentation to determine how the product may contribute toward applicable LEED credits.
What Rough Opening and Installation Requirements Apply to BA-PFI 22" × 30"?
The BA-PFI 22" × 30" requires a rough wall opening that is ¼ inch (6 mm) larger than the nominal door size. Following the manufacturer's opening dimensions and installation procedures helps ensure the access door fits the intended wall or ceiling assembly.
Rough Opening and Fit Guidance
For the BA-PFI 22" × 30", prepare a 22¼" × 30¼" rough wall opening. Framing the opening to the manufacturer's recommended dimensions provides the required clearance for the frame, while the 1-inch exposed flange covers the perimeter after installation.
Installation and Application Notes
Keep the following requirements in mind before installation:
- Confirm that the wall or ceiling assembly requires a fire-rated access door with the appropriate fire rating.
- Follow the installation procedure for the applicable assembly, whether gypsum wall, gypsum ceiling, or masonry wall.
- Install the spring kit and fastening hardware according to the manufacturer's installation instructions.
- Consult the Authority Having Jurisdiction (AHJ) to verify project-specific installation and fire-rating requirements before installation.
Looking for more information about fire-rated access doors or the BA-PFI and its installation process? Explore our in-depth resources, including BA-PFI Fire-Rated Access Door: Your 5 Questions Answered and Discover the Benefits of Installing BA-PFI, for practical guidance, product insights, installation considerations, and specification tips.
Who Specifies BA-PFI 22" × 30" and Where Is It Used?
The BA-PFI 22" × 30" is specified for projects requiring fire-rated access to concealed building systems within qualifying wall and ceiling assemblies. It provides an access point for routine inspection and maintenance while meeting the fire-rating requirements of the surrounding assembly when installed according to the manufacturer's instructions.
This model is commonly specified by:
- Architects preparing fire-rated wall and ceiling details
- General contractors managing commercial and institutional construction
- Mechanical, electrical, and plumbing (MEP) contractors requiring access to concealed building services
- Facility managers responsible for ongoing building maintenance
- Building owners and project managers overseeing renovation or new construction projects
The BA-PFI 22" × 30" is suitable for qualifying fire-rated assemblies in a wide range of building types, including:
- Office buildings
- Hospitals and healthcare facilities
- Schools and universities
- Government and municipal buildings
- Hotels and hospitality properties
- Multifamily residential developments
- Industrial and manufacturing facilities
It is commonly installed to provide access to:
- Mechanical equipment
- Electrical systems
- Plumbing components
- Fire sprinkler and fire system components
- Communication and low-voltage cabling.
Commercial and institutional projects frequently require fire-rated access doors in different sizes and configurations to accommodate a variety of wall and ceiling assemblies. As specifications evolve throughout construction, having dependable support can make ordering and product selection more efficient.
Join Pro Club to access contractor pricing, priority customer support, extended return periods, and exclusive member resources designed to support contractors and facility professionals managing recurring fire-rated access door requirements.
Frequently Asked Questions About Fire Rated Insulated Access Doors
- What is a fire-rated insulated access door?
A fire-rated insulated access door is an access panel designed to provide entry to concealed building systems while meeting the fire-resistance requirements of qualifying wall or ceiling assemblies. Unlike standard access doors, insulated models incorporate insulation as part of their tested construction.
- When should a fire-rated insulated access door be used?
A fire-rated insulated access door should be used whenever access is required through a fire-rated wall or ceiling assembly. The selected model should have a fire rating that matches the surrounding assembly and comply with applicable building codes.
- What is the difference between a fire-rated access door and a fire-rated insulated access door?
A fire-rated access door is designed for use in fire-rated assemblies, while a fire-rated insulated access door also incorporates insulation as part of its construction. The insulation forms part of the tested assembly and may be specified based on the product's listing and project requirements.
- What materials are commonly used in fire-rated insulated access doors?
Fire-rated insulated access doors are commonly manufactured with steel doors and frames combined with fire-resistant insulation, such as mineral wool. The exact materials vary depending on the manufacturer and the product's fire-rating certification.
What to Know Before Buying BA-PFI 22" × 30" Fire Rated Insulated Access Door?
Before ordering, review these considerations to help ensure the BA-PFI 22" × 30" is appropriate for your project requirements and instalation conditions.
- Verify the rough wall opening: Prepare a 22¼" × 30¼" opening, which is ¼ inch larger than the nominal door size.
- Match the fire rating to the assembly: Confirm that the selected access door corresponds with the required fire rating of the wall or ceiling assembly.
- Confirm the installation assembly: Determine whether the access door will be installed in a gypsum wall, gypsum ceiling, or masonry wall, and follow the corresponding installation procedure.
- Review ceiling application limitations: Verify that the selected size complies with the manufacturer's listed ceiling limitations for horizontal applications.
- Specify optional configurations before ordering: Include stainless steel construction, alternative latch options, or masonry anchors when required by the project specifications.
- Allow adequate access clearance: Leave sufficient space for the door to open fully and provide convenient access to the concealed building systems behind the wall or ceiling.
The BA-PFI 22" × 30" combines fire-rated construction, insulated steel components, and standard operating hardware in a single access solution for qualifying wall and ceiling assemblies. With multiple standard and optional configurations, compatibility with gypsum and masonry installations, and custom sizing availability, it offers the flexibility to meet a variety of commercial and institutional project requirements.
Request a quote or call us at +1-888-327-5471 to review available sizes, hardware options, and material configurations for your project. Our team can help you specify the BA-PFI Fire Rated Insulated Access Door that aligns with your assembly requirements, installation conditions, and project specifications.
Feedback