30" x 30" BA-FRLC 3-Hour Fire-Rated Laundry Chute Access Doors for Walls
The 30" x 30" BA-FRLC 3-Hour Fire-Rated Laundry Chute Access Door is designed for multifamily, hospitality, healthcare, and institutional projects that require a code-compliant laundry chute intake within a fire-rated wall assembly.
Built from 16-gauge cold-rolled steel with a continuous piano hinge and a handle-operated self-latching slam latch, it helps maintain the fire rating of the chute wall while giving residents and staff a durable, self-closing opening for laundry drops.
Engineered for vertical fire-rated wall assemblies and certified to UL/ULC fire-door test standards, this door suits laundry chute intakes throughout apartments, dormitories, hotels, and healthcare buildings.
Note: Fire-rated access doors do not stop fires from starting; they help slow down the spread of a fire for a limited period.
Why Choose 30" x 30" BA-FRLC 3-Hour Fire-Rated Laundry Chute Access Doors for Walls?
Chute-Intake Fire Rating: Designed for fire-rated laundry chute intake openings and certified to UL 10B, NFPA 252, and CAN/ULC S104 fire-door test standards, so the intake maintains the rating of the chute wall.
Self-Closing and Self-Latching: Provided with springs so the door is self-closing and self-latching, supporting code-required closure at the chute opening.
Rugged 16-Gauge Steel: A 16-gauge cold-rolled steel door and frame with a 2½" frame depth stands up to constant use in shared laundry areas.
Continuous Piano Hinge: Helps ensure smooth, reliable operation.
Field-Ready Finish: White powder coat primer is ready for field painting to match finished walls.
Not sure if the BA-FRLC is the right fit for your laundry chute intake? Our product experts can compare models, confirm specifications, and help you choose the right solution. Reach out today.
Key Product Specifications
Door Size: 30" x 30"
Weight: 22.8 to 62.9 lbs (varies by size)
Material: 16-gauge cold-rolled steel door and frame
Frame Depth: 2½"
Flange: Exposed flange, 1" wide
Hinge: Continuous piano hinge (located on the height dimension)
Latch: 4" handle-operated self-latching slam latch
Closure: Self-closing and self-latching (springs provided)
Inside Release: Inside panel release standard
Certification: UL 10B, NFPA 252, CAN/ULC S104
Finish: White powder coat primer, ready for field painting
Custom sizing within the model's rated size limits
LEED Compatibility
The BA-FRLC is LEED v4 compliant and can support projects pursuing green building certification. Coordinate product selection with your project's LEED credit strategy and confirm current requirements with your design team.
Need a non-standard size, material, or configuration? Explore our customization options and submit the form to request a solution tailored to your project.
What to Know About Rough Opening and Installation Requirements?
Required Rough Opening
The BA-FRLC rough wall opening is door size + 1/4” or + 6 mm. Confirm the exact opening before framing and note that hinges are located on the height dimension.
Installation Notes
Install only in a vertical fire-rated chute wall consistent with the door's certification.
Locate hinges on the height dimension as required.
Install the provided springs so the door is self-closing and self-latching.
The white powder coat primer is suitable for field painting after installation.
For step-by-step guidance, explore this installation guidepacked with practical instructions for getting the job done right.
Who Specifies BA-FRLC and Where Is It Used?
The BA-FRLC is typically specified by architects, general contractors, mechanical subcontractors, and facility managers responsible for code-compliant laundry chute systems.
Common applications include:
Apartment and condominium buildings - resident laundry chutes
Student housing and dormitories - shared chute intakes
Hotels and hospitality - back-of-house laundry chutes
Hospitals and senior living - institutional laundry chutes
Mixed-use developments - multifamily chute systems
Looking to get more value from every order? Join Pro Club, an exclusive membership designed for contractors and procurement professionals. The program includes exclusive pricing, priority customer support, extended return periods, and member-only resources that help make purchasing faster and project management easier.
Frequently Asked Questions About Fire-Rated Laundry Chute Access Doors
What is a laundry chute intake door?
It is the access door at each floor where laundry is dropped into the chute. This model is built into the fire-rated chute wall and is designed to maintain the wall's fire rating at the opening.
What fire certifications does this door carry?
It is certified to recognized fire-door test standards including UL 10B, NFPA 252, and CAN/ULC S104. Confirm the specific rated size and configuration for your assembly against the submittal documentation.
Is the door self-closing?
Yes. Springs are provided so the door is self-closing and self-latching once installed, which supports code-required closure at the chute intake.
Can the door be opened from inside?
An inside panel release is standard on doors larger than 12" x 12", allowing the panel to be opened from inside the chute.
Get Code-Minded Chute Access for Your Project
Need help selecting the right fire-rated laundry chute access door? Contact our product specialists at +1-888-327-5471 for assistance, available sizes, certifications, and configurations.